ProDAQ 3808
8-Channel 100 MHz Counter/Timer/Frequency Meter
Function Card
-
8 Channels
-
100 MHz Resolution
-
25 MHz Frequency Counter
-
25 MHz Event Counter
-
Pulse Width & Time Interval Measurement
-
Programmable Threshold per Channel
-
128 Words/Channel FIFO
-
Up to 48 Counter/Timer Channels per VXIbus Module
-
Fully synchronizeable with ProDAQ 3424/3550
The ProDAQ 3808 Counter Timer Function
Card is an enhanced version of the ProDAQ 3806
Counter Timer Function Card.
The ProDAQ 3808 Counter Timer Function
Card is designed to operate in one of three
modes: pulse counter, frequency meter or time
interval counter.
In the Pulse Counter Mode and Frequency
Measurement Mode incoming signals of up to 25
MHz can be processed on each of the six channels.
A time interval counter range is divided
into six sub-ranges covering times from 40ns to
20000s with a maximum resolution of 10ns.
Every channel of the 3808 Counter Timer
Function Card has two different counters: a
32-bit pulse counter and a 24-bit time interval
counter, allowing simultaneous operation as a
pulse and a time interval counter.
The time interval counter can count consecutive
time intervals and store the results in a FIFO
memory. This allows the time interval averaging
to be performed resulting in increased time
measurement accuracy. Up to 128 time values
per channel can be stored in the onboard FIFO.
”On-the-fly” readouts can be performed during
the measurement cycle.
The time interval can be defined by selecting
either rising, falling or consecutive edges of the
input signal.
The pulse and time interval counters are globally
enabled by the gate signal, which can be
generated either internally, externally or by software.
In addition, the trigger signal (common or
seperate for every channel) can be used to gate
the time interval measurements. This provides
two modes of operation: a window mode, in
which the trigger enables measurements for the
time duration of the trigger pulse and a launch
mode, in which the trigger starts the measurements.
Each mode can be programmed independently
on a channel-to-channel basis.
Input signals can be either DC or AC coupled
with 1MOhm or 50Ohm termination. Every channel
has a 10-bit digital-to-analog converter to set a
threshold within the full-scale input signal range
of ± 5V.
The ProDAQ 3808 Counter Timer Function
Card is supplied with a VXIplug&play driver, that
can be used with all popular software packages.
The driver automatically detects and initializes
all function cards installed in a ProDAQ motherboard
module, removing any possibility of configuration
errors.
The ProDAQ modules allow the user to safely
and simply expand their existing hardware and
software systems.
Download the datasheetfor the ProDAQ 3808 Function Card ...
|